We help the world growing since 1983

BYS Male Y Tube to Pipe Brass One Touch Fittings 12-445 50-569 1169

Short Description:


Product Detail

Product Tags

BYS Male Y 2 12-445 50-569 1169

Mod. A D F H L M SW
BYS-4-M5 4 M5 18 4 26.5 9 -
BYS-6-M5 6 M5 24.5 4 29.5 12.5 -
SBYS-4-G02 4 Gl/8 18 5.5 38 9 12
SBYS-6-G02 6 Gl/8 24.5 5.5 41.5 12.5 12
SBYS-8-G02 8 Gl/8 28.5 5.5 48.5 14.5 14
SBYS-8-G04 8 Gl/4 28.5 7 50 14.5 14

 

Interchangeability for reference

Parker :

Eaton/WeatherHead : 1107x4M 1107×6M 1107x8M 1107×10M

Midland : 20-557

Camozzi :ND656053-00 ND6560 04-00 ND6560 06-00 ND6560 08-00

BYS Male Y O-ring

attention please :Quotations and delivery of non-stock items supplied on request. Configurations and dimen sions subject to change without notice. 

Metal/Brass Push-In Fittings

Features

  1. Simply to install & uninstall with no tools.
  2. Stainless steel tube locking mechanism.
  3. Thread sealant on taper threads, O-ring face seal on G threads.
  4. NBR as the standard sealing material,other materials are available upon request.
  5. Nick plated is standard for bass surface treatment, ensure anti-corrosion and anti-contamination.
  6. Reuseable-Can be assembled and disassembled repeatedly. (recommend to cut the surface-damaged part of tube)
  7. Thread: BSPP, BSPT, NPT (Please contact us for other styles)

Construction

Brass Push To Connect Fitting

Specification

O-Ring Seal NBR (other materials are available upon request)
Gripping Mechanism Stainless Steel
Temperature Range 32° F to 176°F (higher temperature are possible with special O-rings)
Pressure Max 230 PSI (mainly limited by tube’s enduring)
Vacuum Duty 29.5 Inch Hg
Media Compressed Air

Note: These meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application.

Installation Instructions

Thermoplastic Push In Fittings Assemble Thermoplastic Push In Fittings Disconnect
Figure 1 Figure 2

To connect tube (see figure 1)

  1. Cut tubing squarely–maximum of 15° angle allowable.Use of tube cutter (PTC) is recommended.
  2. Check that port or mating part is clean and free of debris.
  3. Insert tube into fitting until it bottoms.Push twice to verify that tubing is inserted past collet & O-Ring.
  4. Pull on tubing to verify it is fully inserted.

To disconnect tube (see figure 2)

  1. Simply press release button, hold against body, and pull tubing out of fitting.