BLL Extended Male Elbow Tube to Pipe Brass One Touch Fittings
Mod. | A | D | C | E | F | H | M | SW | SW1 |
BLL-M6-G02 | 6 | Gl/8 | 4 | 33.8 | 12.7 | 5.5 | 20 | 9 | 12 |
BLL-M6-G04 | 6 | Gl/4 | 4 | 34 | 12.7 | 7 | 20 | 9 | 14 |
BLL-M8-G02 | 8 | Gl/8 | 5 | 34.8 | 14.2 | 5.5 | 22.5 | 11 | 12 |
BLL-M8-G04 | 8 | Gl/4 | 5 | 55 | 14.2 | 7 | 22.5 | 11 | 14 |
Interchangeability for reference
Parker : 169PLMX-4M-M5 169PLMX-4M-2G 169PLMX-6M-2G 169PLMX-6M-4G 169PLMX-8M-2G 169PLMX-8M-4G 169PLMX-10M-4G 169PLMX-10M-6G 169PLMX-12M-4G 169PLMX 12M-6G 169PLMX-14M-8G
Eaton/WeatherHead :
Midland :
Camozzi :
attention please :Quotations and delivery of non-stock items supplied on request. Configurations and dimen sions subject to change without notice.
Metal/Brass Push-In Fittings
Features
- Simply to install & uninstall with no tools.
- Stainless steel tube locking mechanism.
- Thread sealant on taper threads, O-ring face seal on G threads.
- NBR as the standard sealing material,other materials are available upon request.
- Nick plated is standard for bass surface treatment, ensure anti-corrosion and anti-contamination.
- Reuseable-Can be assembled and disassembled repeatedly. (recommend to cut the surface-damaged part of tube)
- Thread: BSPP, BSPT, NPT (Please contact us for other styles)
Construction
Specification
O-Ring Seal | NBR (other materials are available upon request) |
Gripping Mechanism | Stainless Steel |
Temperature Range | 32° F to 176°F (higher temperature are possible with special O-rings) |
Pressure Max | 230 PSI (mainly limited by tube’s enduring) |
Vacuum Duty | 29.5 Inch Hg |
Media | Compressed Air |
Note: These meant only as a guide to aid in design. Field testing should be performed to find the actual values for your application.
Installation Instructions
Figure 1 | Figure 2 |
To connect tube (see figure 1)
- Cut tubing squarely–maximum of 15° angle allowable.Use of tube cutter (PTC) is recommended.
- Check that port or mating part is clean and free of debris.
- Insert tube into fitting until it bottoms.Push twice to verify that tubing is inserted past collet & O-Ring.
- Pull on tubing to verify it is fully inserted.
To disconnect tube (see figure 2)
- Simply press release button, hold against body, and pull tubing out of fitting.